If the appliance is fitted with a water softener, the drain must not be connected to a siphon
with valve ! water softener will be out of use
Refer to the connection diagram for the maximum permitted height of wall drains – (see TECHNICAL
DATA)
Caution: make sure that the intake and drain hoses are not bent, constricted or crushed
after installation.

4.2 Electrical connection

The dishwasher and any additional equipment must be connected to the electrical
system by authorised, skilled staff, in accordance with the relevant regulations; also
comply with the technical instructions for the connection.
The total rated power is stated on the appliance's technical data plate.
The electrical protection devices fitted for the dishwasher must serve this appliance
only.
The user must have a master switch and a differential safety breaker, with rating
suitable for the appliance's characteristics, installed on the electricity supply line in
accordance with the relevant regulations.
These switches must be installed close to the dishwasher, be easily accessible after
installation, and provide complete disconnection from the electrical mains in
overvoltage class III conditions.
Warning !!!
The dishwasher is always powered up unless the master switch is turned off.
Connect the appliance to the user's earth system. The
in the bottom right-hand corner of the appliance.
The earth wire (PE) is yellow-green in colour, the neutral wire (N) is blue and the live
wires (L1, L2, L3) are black, grey and brown.
In the event of single-phase connection (230V-1N~), the connection to the electrical
mains must be made using a cable with plug compliant with the relevant regulations.
THE POWER SUPPLY CABLE, AS PROVIDED, MUST BE REPLACED BY THE
MANUFACTURER OR AN AUTHORIZED SERVICE CENTER IN COMPLIANCE WITH THE
SPECIFICATIONS PROVIDED ON ELECTRICAL DIAGRAM SUPPLIED IN THE MACHINE IN
ORDER TO PREVENT ALL RISKS.
GSM620-G
8
terminal for the connection is