Spezifikationen
esb7214PortState
esb7214PortSwitchCount
esb7214PortStartupMode
esb7214PortStartupDelay
esb7214PortRepowerTime
esb7214PortResetDuration
esb7214ActiveInputs
esb7214InputIndex
esb7214Input
esb7214InputName
esb7214POE
esb7214PwrSupplyIndex
esb7214PwrSupplyStatus
esb7214NTPTimeValid
esb7214NTPUnixTime
esb7214NTPLastValidTimestamp
esb7214SensorIndex
esb7214TempSensor
esb7214HygroSensor
esb7214InputSensor
esb7214AirPressure
esb7214DewPoint
esb7214DewPointDiff
esb7214ExtSensorName
esb7214ExtActiveInputs
esb7214ExtInputIndex
esb7214ExtInput
esb7214ExtInputName
esb7214ExtInputPortNum
esb7214ExtInputBlockIndex
4.11 SSL
TLS Standard
93
Expert Sensor Box 7213/7214
A textual string containing name of a Relay Port.
.67.1.3.1.2.1.3.x
current state of a Relay Port
.67.1.3.1.2.1.4.x
The total number of switch actions ocurred on a Relay Port. Does not
count switch commands which will not switch the ralay state, so just real
relay switches are displayed here.
.67.1.3.1.2.1.5.x
set Mode of startup sequence (off, on , remember last state)
.67.1.3.1.2.1.6.x
Delay in sec for startup action
.67.1.3.1.2.1.7.x
Delay in sec for repower port after switching off
.67.1.3.1.2.1.8.x
Delay in sec for turning Port on again after Reset action
.67.1.5.6.1.0
Number of suppported Input Channels.
.67.1.5.6.2.1.1.x
None
.67.1.5.6.2.1.2.x
Input state of device
.67.1.5.6.2.1.32.x
A textual string containing name of the Input
.67.1.5.10.0
signals POE availability
.67.1.5.13.1.1.x
Index of Power Supply entries
.67.1.5.13.1.2.x
shows status of the Power Supply 1 = fst, 2 = snd etc.
.67.1.5.15.1.0
Show if valid Time is received
.67.1.5.15.2.0
show received NTP time as unixtime (secs since 1 January 1970)
.67.1.5.15.3.0
show seconds since last valid NTP timestamp received
.67.1.6.1.1.1.x
None
.67.1.6.1.1.2.x
actual temperature
.67.1.6.1.1.3.x
actual humidity
.67.1.6.1.1.4.x
logical state of input sensor
.67.1.6.1.1.5.x
actual air pressure
.67.1.6.1.1.6.x
dew point for actual temperature and humidity
.67.1.6.1.1.7.x
difference between dew point and actual temperature (Temp -
DewPoint)
.67.1.6.1.1.32.x
A textual string containing name of a external Sensor
.67.1.6.2.1.0
Number of suppported Input Channels.
.67.1.6.2.2.1.1.x
None
.67.1.6.2.2.1.2.x
Input state of device
.67.1.6.2.2.1.32.x
A textual string containing name of the Input
.67.1.6.2.2.1.33.x
Number of external Sensor Port when value greater zero, else device
built-in Input.
.67.1.6.2.2.1.34.x
Either index of device built-in Input, or index of Input in external sensor.
INTEGER
RW
Integer32
RO
INTEGER
RW
Integer32
RW
Integer32
RW
Integer32
RW
Unsigned32
RO
Integer32
RO
INTEGER
RO
OCTETS
RW
Integer32
RO
Integer32
RO
INTEGER
RO
INTEGER
RO
Unsigned32
RO
Unsigned32
RO
Integer32
RO
Integer32
RO
Integer32
RO
INTEGER
RO
Integer32
RO
Integer32
RO
Integer32
RO
OCTETS
RW
Unsigned32
RO
Unsigned32
RO
INTEGER
RO
OCTETS
RW
Integer32
RO
Integer32
RO