Spezifikationen
port set {port_num}
extinput {port_num} {inp_num} {LOW=0|HIGH=1}
port show
extinput {port_num} {inp_num} {LOW=0|HIGH=1}
state set {OFF=0|ON=1|DISABLED=2}
extinput {port_num} {inp_num} {LOW=0|HIGH=1}
state show
extsensor
extsensor all show
extsensor all show
extsensor {port_num} {sen_field} value show
extsensor {port_num} {sen_type} label set
"{name}"
extsensor {port_num} {sen_type} label show
extsensor {port_num} type show
extsensor {port_num} {sen_type} {sen_field}
events set {off=0|on=1}
extsensor {port_num} {sen_type} {sen_field}
events show
extsensor {port_num} {sen_type} {sen_field}
events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5,EVT_DISPLAY=6,EVT_CONSOLE=7,EVT_M
QTT=8}"
extsensor {port_num} {sen_type} {sen_field}
events type show
extsensor {port_num} {sen_type} {sen_field}
maxval set {num}
extsensor {port_num} {sen_type} {sen_field}
maxval show
extsensor {port_num} {sen_type} {sen_field}
minval set {num}
extsensor {port_num} {sen_type} {sen_field}
minval show
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
extsensor {port_num} {sen_type} {sen_field} hyst
show
extsensor {port_num} {sen_type} {sen_field}
publish mode set {NONE=0|INTERVAL=1|
DELTA=2|INTERV_DELTA=3}
extsensor {port_num} {sen_type} {sen_field}
publish mode show
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain set {OFF=0|ON=1}
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain show
extsensor {port_num} {sen_type} {sen_field}
publish timer set {num_secs}
extsensor {port_num} {sen_type} {sen_field}
publish timer show
extsensor {port_num} {sen_type} {sen_field}
publish delta set {float}
extsensor {port_num} {sen_type} {sen_field}
publish delta show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
extsensor period show
extsensor {port_num} {sen_field} calib set {float}
extsensor {port_num} {sen_field} calib show
http
71
Expert Sensor Box 7213/7214
shows Port for Power Port Switching actions
sets Port state for Power Port Switching actions
shows Port state for Power Port Switching actions
enters cmd group "extsensor"
shows all values from connected external sensors
shows all plugged sensors and fields
shows sensor value
sets sensor name to label
shows label of sensor
shows type of sensor
enables sensor events on/off
shows if sensor events are enabled
enables different event types
shows what event types are enabled
sets maximum value for sensor
shows maximum value for sensor
sets minimum value for sensor
shows minimum value for sensor
sets hysterese value for sensor
shows hysterese value for sensor
sets publish mode
shows publish mode
sets mqtt retain
shows if mqtt retain set
sets publish time interval
shows publish time interval
sets publish delta value
shows publish delta value
sets Port for Power Port Switching actions
shows Port for Power Port Switching actions
sets Port state for Power Port Switching actions
shows Port state for Power Port Switching actions
sets sensor Min/Max measurement period
shows sensor Min/Max measurement period
sets calibration offset for temperature or humidity
shows calibration offset for temperature or
humidity
enters cmd group "http"
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
© 2023 GUDE Systems GmbH