Herunterladen Diese Seite drucken

CONDTROL XLINER 360 G Bedienungsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für XLINER 360 G:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
EN
LASER LEVEL
ACCURACY CHECK
Check of horizontal line
Check of horizontal line is carried out by using 2 walls A and B located
opposite each other at 5m distance.
1. Install the laser level as close as possible to wall A (see Fig.A). Unlock
compensator and switch on vertical and horizontal lines. Expand the
device emitters in the direction of wall A so that the crossing of the
laser lines on the wall is located in front of the laser level. Mark the
crossing point of laser lines as A1. Mark point B on the wall B.
2. Turn the instrument by 90°. Check misalignment of horizontal line
and point B1 (see Fig. B). If deviation between the laser line and the B1
mark exceeds 1 mm, please contact service center.
3. Repeat step 2 for 2 more times, turning the laser level in one
direction.
A
XLiner 360 G / COMBO 360 G
5
m
user manual
11
11

Werbung

loading

Diese Anleitung auch für:

Xliner combo 360 g