8.3.
Installation of the appliance in a line
To fix the appliance in a line (neighboring) follow
the steps:
1. Dismantle the control panel, and remove the
cast iron frame from the chimney if necessary.
2. Apply the sealing tape (A) onto the joining
sides.
Z
8.4.
Connection to the mains (service technician)
The device may be connected to the power supply
only by the authorized and qualified personnel,
when the valid regulations are followed and when
appropriate material is used in accordance to the
regulations.
The device is delivered adjusted to 400V 3N~
50/60 Hz working voltage.
The correct cross section of the cable is
presented in the attachments and should be
determined by the electrician.
To prevent any risks the damaged
supply cable must be replaced only by the
manufacturer or electrician.
Before connection to the power
supply, make sure that the device has
been initially connected with the
appropriate all-pole switch with a contact
opening of min. 3 mm.
To correctly connect the device, follow the
guidelines below.
Remove the cover from the terminal strip (A).
3. Place the appliances next to each other and in
a horizontal position (by adjusting the feet).
4. Connect the appliances with the joining
elements.
i
A
Connect the switch-off to the terminal strip (B)
of the device, as shown in the drawing and
block diagram (see the attachment). Use the
H07RN-F cable or better.
Firmly press the end of the cable (C).
Replace the terminal strip cover.
B
C
13
ENGLISH
A
g
GB

Werbung

loading

Diese Anleitung auch für:

Id092m01296318296319