7.3.
Generator's error messages (E1)
Error code
Name
E1 ↔ 01
Overload current
No induction
E1 ↔ 02
current
IGBT temperature
E1 ↔ 03
too high
Cooking zone
E1 ↔ 04
temperature too
high or too low
Broken cable at
E1 ↔ 05
the control unit
Internal
E1 ↔ 06
temperature too
high or too low
Inductor
E1 ↔ 07
temperature
Mains voltage
E1 ↔ 08
phases
E1 ↔ 10
Communication
E1 ↔ 11
Start-up
Power supply
E1 ↔ 13
connection:
Power adapter
E1 ↔ 14
error
Empty pot
E1 ↔ 15
protection
Possible reason
Inappropriate cookware
Defective or damage inductor
No inductor or current at the
power dividers
Air vents blocked, fan
contaminated, faulty IGBT
temperature sensor
Empty pot
Defective temperature sensor
Defective output stage
Cable has a loose contact or is
broken
Digital service has a wrong ID.
Control unit error
Air vents blocked, contaminated
fan, faulty internal temperature
sensor
Inductor temperature too high
Defective temperature sensor
No mains voltage phase or
insufficient network quality
LIN or CAN-bus error, no
connection between the keypad
and the generator
Unnecessary service field
connected
Digital service field has an
incorrect ID
Error during start-up of the
equipment
Error when the supply voltage
is too high or too low
Error when the supply voltage
is too high or too low
Power supply error
Empty pot
Defective temperature sensor
11
ENGLISH
Solution
Use appropriate cookware
Check the inductor
Connect the inductor
Clear the air vents
Clean the fan
Contact the service company.
Remove the pot, switch the cooker
off and wait a few minutes until the
cooking zone cools down.
Replace the sensor
Replace the generator
Switch the generator off, check the
cable, replace if necessary
Switch the generator off, check the
DIP switch, possibly switch on.
Check / replace a control unit
Clear air vents, clean the fan
Remove pots, switch off and wait a
few minutes until cooking zones
cool down
Replace sensor
Check mains voltage phases
Disconnect the device from the
power supply and check the
connection
Set the service field or connect to
the appropriate controller
Switch the generator off and set
the DIP switch correctly
Wait approx. 30 seconds for the
device to update automatically
Check the power supply
connection
Check the power supply
connection
Turn off the main protection and turn
it on again after a few seconds
Remove the pot, switch off and
wait a few minutes until cooking
zone cools down.
Replace the temperature sensor
GB