Elektromagnetischer durchflussmesser / messumformer gefahrenbereiche atex / iecex bereiche 2, 21 und 22
Vorschau ausblenden Andere Handbücher für WaterMaster FET100:

Werbung

WaterMaster FET100
Elektromagnetischer Durchflussmesser / Messumformer
Certificate No.:
Date of Issue:
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
See attachment
CONDITIONS OF CERTIFICATION: YES as show n below :
1. Suitable precautions to prevent mechanical damage to the remote terminal housing shall be taken if the enclosure is to
be installed in an area of high mechanical danger.
2. The non-metallic material of the remote terminal housing may store electrostatic charge and become a source of ignition
in applications w ith a low relative humidity <~30% relative humidity w here the surface is relatively free of surface
contamination such as dirt, dust, or oil. Guidance on protection against the risk of ignition due to electrostatic discharge
can be found in EN TR50404 and IEC TR60079-32 (in preparation). Cleaning of the surface should only be done w ith a
damp cloth.
3. The temperature at the entry point of the transmitter and remote sensor under rated conditions is higher than 70 °C.
Cables rated for 100°C should be used.
Abb. A.11 IEC-Typenprüfungszertifikat Nr.: IECEx FME10.0006X (Seite 3 von 3)
OI/FET100/ATEX–DE Rev. A
IECEx Certificate
of Conformity
IECEx FME 10.0006X
2012-09-17
Schedule
Issue No.: 0
Page 3 of 3