Spezifikationen
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
extsensor {port_num} {sen_type} {sen_field} hyst
show
extsensor {port_num} {sen_type} {sen_field}
publish mode set {NONE=0|INTERVAL=1|
DELTA=2|INTERV_DELTA=3}
extsensor {port_num} {sen_type} {sen_field}
publish mode show
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain set {OFF=0|ON=1}
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain show
extsensor {port_num} {sen_type} {sen_field}
publish timer set {num_secs}
extsensor {port_num} {sen_type} {sen_field}
publish timer show
extsensor {port_num} {sen_type} {sen_field}
publish delta set {float}
extsensor {port_num} {sen_type} {sen_field}
publish delta show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
extsensor period show
extsensor beeper set {OFF=0|ON=1}
extsensor beeper show
extsensor {port_num} {sen_field} calib set {float} sets calibration offset for temperature or humidity
extsensor {port_num} {sen_field} calib show
http
http server set {HTTP_BOTH=0|HTTPS_ONLY=1|
HTTP_ONLY=22|HTTPS_REDIR=3}
http server show
http port set {ip_port}
http port show
http portssl set {ip_port}
http portssl show
http tls mode set {TLS12=0|TLS13_12=1|TLS13=2|
TLS13_12_11=3}
http tls mode show
http auth mode set {BASIC=0|SESSION=1|
SESSION_EXT=2}
http auth mode show
http passw d enabled set {OFF=0|ON=1}
http timeout admin set {num_secs}
http timeout admin show
http timeout user set {num_secs}
http timeout user show
http passw d enabled show
http passw d local set {OFF=0|ON=1}
Expert Power Control 8041/8045
sets hysterese value for sensor
show s hysterese value for sensor
sets publish mode
show s publish mode
sets mqtt retain
show s if mqtt retain set
sets publish time interval
show s publish time interval
sets publish delta value
show s publish delta value
sets Port for Pow er Port Sw itching actions
show s Port for Pow er Port Sw itching actions
sets Port state for Pow er Port Sw itching actions
show s Port state for Pow er Port Sw itching
actions
sets sensor Min/Max measurement period
show s sensor Min/Max measurement period
enables beeper sensor alarms
show s if beeper sensor alarms are enabled
show s calibration offset for temperature or
humidity
enters cmd group "http"
sets accepted connection types
show s accepted connection types
sets http port
show s http port
sets https port
show s https port
restricts TLS mode
show s TLS mode restriction
sets http session authentication mode
show s http session authentication mode and
compatibility
enables http passw ord on/off
sets admin session timeout
show s admin session timeout
sets user session timeout
show s user session timeout
show s if http passw ord enabled
enables local login on/off
6
6
6
6
6
6
84