Herunterladen Inhalt Inhalt Diese Seite drucken

GUDE Systems Expert Power Control 8041 Serie Anleitung Seite 77

Inhaltsverzeichnis

Werbung

Spezifikationen
rcmb {mod_num} {RMS=0|DC=1} events set
{OFF=0|ON=1}
rcmb {mod_num} {RMS=0|DC=1} events show
rcmb {mod_num} {RMS=0|DC=1} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_BEEPER=5,EVT_DISPLAY=6,EVT_CONSOLE=
7,EVT_MQTT=8}"
rcmb {mod_num} {RMS=0|DC=1} events type
show
rcmb {mod_num} {RMS=0|DC=1} events beeper
mode set {CONTINOUS=0|INTERMITTENT=1}
rcmb {mod_num} {RMS=0|DC=1} events beeper
mode show
rcmb {mod_num} {RMS=0|DC=1} maxval set
{float}
rcmb {mod_num} {RMS=0|DC=1} maxval show
rcmb {mod_num} {RMS=0|DC=1} minval set {float} sets minimum value for sensor
rcmb {mod_num} {RMS=0|DC=1} minval show
rcmb {mod_num} {RMS=0|DC=1} hyst set {float}
rcmb {mod_num} {RMS=0|DC=1} hyst show
rcmb {mod_num} {RMS=0|DC=1} publish mode set
{NONE=0|INTERVAL=1|DELTA=2|
INTERV_DELTA=3}
rcmb {mod_num} {RMS=0|DC=1} publish mode
show
rcmb {mod_num} {RMS=0|DC=1} publish mqtt
retain set {OFF=0|ON=1}
rcmb {mod_num} {RMS=0|DC=1} publish mqtt
retain show
rcmb {mod_num} {RMS=0|DC=1} publish timer set
{num_secs}
rcmb {mod_num} {RMS=0|DC=1} publish timer
show
rcmb {mod_num} {RMS=0|DC=1} publish delta set
{float}
rcmb {mod_num} {RMS=0|DC=1} publish delta
show
rcmb {mod_num} {RMS=0|DC=1} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
set {port_num}
rcmb {mod_num} {RMS=0|DC=1} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
show
rcmb {mod_num} {RMS=0|DC=1} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state set {OFF=0|ON=1|DISABLED=2}
rcmb {mod_num} {RMS=0|DC=1} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
snmp
snmp port set {ip_port}
snmp port show
snmp snmpget enabled set {OFF=0|ON=1}
snmp snmpget enabled show
snmp snmpset enabled set {OFF=0|ON=1}
snmp snmpset enabled show
snmp snmpv2 enabled set {OFF=0|ON=1}
snmp snmpv2 enabled show
snmp snmpv2 public set "{text}"
snmp snmpv2 public show
snmp snmpv2 private set "{text}"
snmp snmpv2 private show
snmp system {CONTACT=0|NAME=1|
LOCATION=2} set "{text}"
77
Expert Power Control 8041/8045
enables sensor events on/off
show s if sensor events are enabled
enables different event types
show s w hat event types are enabled
sets beeper tone
show s beeper tone
sets maximum value for sensor
show s maximum value for sensor
show s minimum value for sensor
sets hysterese value for sensor
show s hysterese value for sensor
sets publish mode
show s publish mode
sets mqtt retain
show s if mqtt retain set
sets publish time interval
show s publish time interval
sets publish delta value
show s publish delta value
sets pow er port for sensor values action
show s pow er port for sensor values action
sets state for sensor values action
show s state for sensor values action
enters cmd group "snmp"
sets SNMP UDP port
show s SNMP UDP port
enables SNMP GET cmds on/off
show if SNMP GET cmds are enabled
enables SNMP SET cmds on/off
show if SNMP SET cmds are enabled
enables SNMP v2 on/off
show if SNMP v2 is enabled
enables SNMP v3 on/off
show if SNMP v3 isenabled
sets SNMP v2 public cummnity
show s SNMP v2 public community
sets sysLocation/sysName/sysContact