In case of loud noise from the pump, proceed as follows:
OBSERVATION
Pump is making loud
noise
Note regarding excessive temperatures:
In order to protect the electronics from temperatures that are
dangerously high, the electronic control system monitors its own
temperature. If the measured temperature is too high the pump speed
is reduced. If the temperature rises above a safety limit, the pump will
shut itself off. The pump will automatically restart after cooling down.
10.
Disposal
This product and parts thereof must be disposed of in an
environmentally friendly manner. Applicable local regulations must be
followed.
11.
Exploded View (see figure 6)
1.
Plug for the supply cable
2.
Stator/pump motor with receptacle for the plug
Pump is in air purge mode for 10
cycles. X= cycle count
Low voltage error.
High voltage error.
Overtemperature error.
Overcurrent error.
Motor start error.
Position sensing error.
Offset error.
POSSIBLE REASON
Not thoroughly vented
Foreign objects in pump
Worn out bearing
23
-
Check the mains voltage
Check the mains voltage
Let the pump cool down
Check for foreign object
blocking the pump rotor (
Section 8)
Electronics board defect,
non-serviceable
ACTION
See section 7.2 "Getting
Started"
See section 8
"Maintenance/Disassembly"
Replace pump