Herunterladen Diese Seite drucken

Mennekes AMTRON Start Betriebs Und Installationsanleitung Seite 53

Vorschau ausblenden Andere Handbücher für AMTRON Start:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.3 Checking the device
Test according to IEC 60364-6 and the applicable nation-
al regulations (e.g. in Germany: DIN VDE 0100-600)
Prior to the initial setting-up process, carry out an inspec-
tion of the charging station in accordance with IEC 60364-
6 and the applicable national regulations (e.g. in Germany:
DIN VDE 0100-600). The test can be carried out in connec-
tion with the MENNEKES test box and a standard-compliant
test equipment. The MENNEKES test box simulates vehicle
communication. Test boxes are available as accessories
from MENNEKES.
f Perform a standard test before releasing the device.
Operating instructions of the test box.

7. Operation
7.1
Key switch
Only available for the equipment variants Basic (E/R) and
Standard E.
Fig.: 20. Key switch
Position 0
Charging cannot be started when the switch is in the
standby position.
Position I
The charging function is active for as long as the key is
in this position. It cannot be pulled out. If charging is not
started and the key is turned back to the standby position,
the ready for charging state remains active for approx. 65
seconds.
If charging is started and the key is turned back to the
standby position, charging continues until the vehicle is
fully charged.
Position II
The charging function is permanently activated and the key
can be removed. If the key is turned back to the standby
position, the charging function is deactivated and the
charging process is interrupted.
EN
21

Werbung

loading