To prevent the ingress of rainwater, the hole in
the membrane should not be larger than the
cables.
Fig.: 16. Attach to the wall
f Screw the unit to the wall using dowels (1), screws (2)
and plugs (3).
f Check the device for firm and secure attachment.
5.6 Electrical connection
Connecting the supply line
1
2
Fig.: 17. Terminals
f Strip 370 mm supply line.
f Strip 12 mm core insulation.
f Connect the cable cores (2) to the terminal block (1)
according to the circuit diagram.
When routing the supply line, observe the permis-
sible bending radius.
f Check that the individual cores are properly connected
and the screws tightened.