3.11 LED Info bar
The LED information field indicates the operating status of the device. Operational readiness, charging, wait time, and
faults are indicated by four symbols in the colours blue, green, white, and red.
LED Info bar
lit blue permanently
flashes blue
pulsating green
lit green permanently
flashes green
steady white
flashes white
lit or flashing red
The colour scheme (green / blue) for "Ready for operation / charging" depends on the configuration during the
setting-up process.
Ready for operation
The device is ready for use. No vehicle is connected to the device.
Ready for operation: Starting the charging process
„ The device was authorized via the key switch for a single charge. No vehicle is con-
nected to the device.
„ The vehicle is connected to the device. The charging process does not start due to a
missing activation signal or a charging current configuration of 0 A.
Ready to charge: vehicle pauses
All requirements for charging an electric vehicle are met. A charging process is not tak-
ing place. The charging process is paused due to a vehicle feedback or was terminated
by the vehicle.
Charging process active
All requirements for charging an electric vehicle are met. Charging in progress.
Charging process active: Excess temperature warning
Charging in progress. The device reduces the charging current to prevent overheating
and deactivation.
Wait period
The charging process on the device was ended. Wait for confirmation from the vehicle.
Wait time: Removing the charging cable
The charging process has finished. Wait for the charging cable to be removed from the
vehicle.
Fault
A fault prevents the vehicle from charging.
Î "9. Remedy"