pencil on the right and left walls in the corner where you
want to mount the hood:
The first pair is the distance between the cooking top and
the hood and will also act as reference for the installation
of the corner brackets.
Attention! The corner brackets are to be installed if
you are not sure that the walls forming the corner are
perfectly perpendicular.
The second pair, 50mm higher than the first, indicates
the positioning of the lower side of the support structure
of the hood.
2.
Place the support structure on the corner of the wall so
that its right and left sides are equidistant from the corner
of the wall (check in addition that the side with the series
of horizontal holes is turned upwards), mark and make
four external holes, insert 4 wall dowels and fix with 4
screws.
3.
Fix the lower support bracket to the support structure with
4 screws.
4.
Check that the corner of the kitchen where you want to
mount the hood has perfectly perpendicular right and left
walls, otherwise install the corner fairings:
Place the corner fairings on the right and left walls.
Note: the lower side of the corner fairings must coincide
with the lower pair of lines previously traced on the wall -
in addition both must coincide with the corner of the wall,
possibly forming a single and continuous frame, from the
right to the left side.
Mark and make 6 holes, insert 6 wall dowels and, with 6
screws and washers, fix the corner brackets to the wall.
5.
Put flues support bracket „G" on the wall, adhering to the
ceiling so that its right and left sides are equidistant from
the corner of the wall, use the flues support bracket as a
perforating diagram and mark 4 holes with the pencil,
make the holes and insert 4 dowels.
Suction version/Filtering version: Fix the flues support
bracket to the wall with 4 screws.
Only filtering version: adjust the extension of deflector
F on the basis of the width of flues support bracket G, fix
the extensions with 2 screws and fix the deflector to the
flues support bracket with 4 screws.
6.
Hook the hood onto the lower support bracket.
7.
a.-b. Insert the lower part of the hood into the suction
unit.
c. Fix the lower part of the hood to the suction unit with 6
screws.
Attention! The hood is not yet definitively fixed to the
wall, every successive operation must therefore be
carried out with caution to avoid the hood unhooking from
the support bracket and causing damage to people or
things.
8.
Carry out the electrical connections between the two
parts.
9.
Adjust the distance of the hood from the wall and the
horizontal setting of the hood, using two adjustment
screws placed on the hooks of the hood.
If the corner brackets have been mounted (corner of
the kitchen NOT perfectly perpendicular): check that
the hood rests perfectly on the corner brackets.
If the corner brackets have not been mounted (corner
of the kitchen perfectly perpendicular):
a. Check that the lower part of the hood is perfectly
horizontal (if mounted correctly, this should coincide with
or be parallel to the lower horizontal line marked on the
wall (see montage operation 1).
b. Mark the two points (right and left) of definitive fixture
with a pencil.
c. Unhook the hood and make 2 holes, insert 2 wall
dowels, hang the hood up again and fix definitively with 2
screws and washers.
10. Fix the motor unit to the support structure definitively:
make a Ø3.5 mm pilot hole on the support structure with
a drill, passing through the lower hole inside the motor
housing, after which fix definitively with 1 screw and
washer.
11. Carry out the connection of a tube (tube and strips for
fixing not supplied, to be purchased) for the discharge of
fumes to the connection ring over the suction motor unit.
The other end of the tube must be connected to a device
for the expulsion of fumes outside in the case of using
the hood in the suction version or to deflector F in the
case of using the hood in the filtering version.
12. Connect the electricity.
13. Place the flues and fix them above with 2 screws (20a) to
the „G" (20b) flues support bracket.
14. Slide the lower section of the chimney to cover the
suction unit completely until it inserts into the apposite
seat over the hood.
15. Apply the two side covers - embedded fixture - the parts
are not interchangeable.
Mount the frame of the carbon filter and the fats filter/s again
and check the perfect functioning of the hood.