Cabling example for screw terminal installation (95 to 240 mm
cables)
U1
V1
W1
Input power cable
UDC+
R-
R+ UDC-
U2
PE
8 N·m (5.9 lbf·ft)
Motor cable
2
V2
W2
b
a. Connect the cable to the terminal. Tighten the
Allen screw to 20...40 N·m (15...30 lbf·ft).
b. Connect the terminal to the drive. Tighten to
30...44 N·m (22...32 lbf·ft).
WARNING! If the wire size is less than
95 mm
be used. A cable of wire size less than
95 mm
terminal will loosen and may damage
the drive.
Quick installation guide - ACSM1-04/04Lx
[AWG3/0 to 500MCM]
a
2
(3/0 AWG), a crimp lug must
2
(3/0 AWG) connected to this
7