Step 6
SET FLOWMETER
1. Check the «Instant Value».
Instant Value: Ensures that the volume consumed indicated on the water meter is the same as the volume
displayed on the application. If a gap is noted, check the wiring (polarity) or adjust the «COEFFICIENT» value.
2. Fill in the remaining fields.
High threshold (daily volume): maximum consumption (in liter) that you do not want to exceed in a period of
24h. If the goal is exceeded you will be alerted immediately (by e-mail and notification smartphone and / or
tablet).
Low threshold (daily volume): minimum consumption (in liters) that you want to achieve over a period of
24h. If the goal is not reached you will be alerted the next day at 7am (by e-mail and notification smartphone
and / or tablet).
Leak alert volume: water volume threshold (in liter) from which you want to be alerted.
Station flow: for each station, read the flowmeter at time T (Cpt1), then at time
T + 5mn (Cpt2).
Make the calculation (Cpt2 - Cpt1) / 5 => Flow (L / min)
In the application fill in the results.
High Threshold (Station Flow Alerts): Maximum consumption warning threshold in % of the calibrated flow of
the channel. The «High threshold» alert is immediate as soon as it is reached.
Low threshold (Station Flow Alerts): Minimum consumption warning threshold in % of the calibrated flow of
the channel. The «High threshold» alert is immediate as soon as it is reached. For each station flow alert you
have the possibility to define the desired type of action:
• No action: watering continues.
• Permanent OFF: resuming watering requires a manual ON command (in the application on the programmer
concerned).
• Inhibit the output: stops the station concerned, requires the acknowledgment of the alert (in the application
on the programmer concerned) to reactivate the station.
Stabilization time:
Time required before the water flow is stable when starting and stopping the station. It eliminates the peak
flow (start) or leak (stop). The time is the same for all stations.
During this period, the consumption is not taken into account for triggering alerts or actions.
+S - C P 1 2 3 4 5 6 C
l/mn
Flowmeter, water meter
Connect your + S - input to a water meter equipped with a flow sensor as shown above. Use dry contact flow
sensors or equivalent. For polarized flow sensors, when wiring,observe the polarization :
Red wire -> + Black wire - > -
5