Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Schedule - Fuxtec Fx-Rm Serie Original Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für FX-RM Serie:
Inhaltsverzeichnis

Verfügbare Sprachen

  • DEUTSCH, seite 1
Original User Manual FUXTEC FX-RM Series_de_en_fr_ita_es_rev24
Regular
Before
maintenance
each use
Engine oil
Check
Change
Air filter
Check
Change
Spark plug
Check
Change
Fuel tank
Check
and filter
Change
Valve
Check
clearance
Change
Combustion
chamber
clean
The engine does not
start
1. Check fuel level
2. Remove and check
the spark plug
3. User errors
4. Impurities
5. Electrical contact

MAINTENANCE SCHEDULE

First month
Every 3
or 5
months or
operating
25 operating
hours
hours
*
*
*
After 200
operating
hours
TROUBLESHOOTING
Possible causes
No more fuel in the tank
Impure gasoline: Engine stored without
care, proper emptying of the tank or
filled with contaminated gasoline
Spark plug defective, dirty, or incorrectly
attached
Spark plug flooded with gasoline
forgotten to operate the brake lever at
start
Fuel filter or carburetor contaminated
When tightening the engine brake lever,
the contact plate at the end of the
Bowden cable does not close
69
Every 6 months or 50
operating hours
operating
*
Troubleshooting
Empty the tank and the carburetor.
Fill up with new fuel (super unleaded)
Replace the spark plug
Dry and reinstall properly
While the starter is pulled, the upper lever
must be pulled to the handle
Replace or clean the components
Bend back the holder to create the
electrical contact
Once a
Every 2
year or
years or
100
250
operating
hours
hours
*
*
*
Refill

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Inhaltsverzeichnis