Disassembly of the diffuser filter VIPVORT
Disassembly of the diffuser filter: disassemble the diffuser filter only after removing the safety screw (See Fig. 3, pos. 5).
Keep the pump motionless and turn the diffuser filter clockwise looking at the pump from the bottom. To reassemble
the diffuser filter, lubricate the O-ring with water and turn the filter counterclockwise (see Fig. 6).
Pump storage instructions
Store the pump in a dry place and protect it from frost.
PROBLEM
1) No electricity.
1) THE ELECTROPUMP DOES
NOT PUMP WATER, THE
MOTOR DOES NOT RUN
2) Plug inserted incorrectly.
3) Enabled safety switch.
4) Blocked impeller.
5) Damaged motor or condenser.
1) Obstructed suction grid.
2) THE PUMP DOES NOT SUP-
PLY WATER BUT THE MOTOR
IS RUNNING
2) Blocked check valve.
3) Air in impeller body (air bubbles).
1) Partially obstructed suction grid.
3) THE PUMP SUPPLIES A
LIMITED AMOUNT OF WATER
2) Obstructed pipe.
3) Worn impeller.
1) Solid particles prevent the free rotation
4) INTERMITTENT OPERATION
2) The temperature of the fluid is too high.
3) Voltage out of range.
4) The fluid is too dense.
5) Faulty motor
Only for EU countries
Do not dispose of electric tools together with household waste material!
In observance of European Directive 2002/96/EC on waste electrical and electronic equipment
and its implementation in accordance with national law, electric tools that have reached the
end of their life must be collected separately and returned to an environmentally compatible
recycling facility.
8
POSSIBLE CAUSE
of the impeller.
4
GB
REMEDY
2) Verify that voltage is present and that the
plug is correctly inserted.
3) Reset the safety switch.If the safety switch
is once more enabled, contact a specialised
electrician.
4) Remove possible obstructions from the
impeller.
5) Contact the Customer Assistance Service.
1) Clean the grid.
2) Clean or replace the valve.
3) Perform several start-ups in order to
remove all the air.
1) Clean the grid.
2) Remove the obstructions
3) Contact the Customer Assistance Service.
1) Remove the foreign particles.
3) Supply the pump in accordance with
nameplate data.
4) Dilute the pumped fluid.
5) Contact the Customer Assistance Service.