Inductive sensors
6
System Functions (continued)
6.4

Variant Configuration

The following three variants are available:
LSSC
AdSS
Comprehensive Condition Monitoring
They differ in the configuration of the process data and of
the available switching profiles.
Furthermore, there are differences in the configuration
options for the switching interval (see chapter 4.3 on
page 26).
In the Comprehensive Condition Monitoring variant, the
configuration of the switching interval behaves as in the
LSSC profile. This profile serves as a full configuration for
the Condition Monitoring functions and supplies all
available data.
After a variant changeover, an inconsistent
configuration may occur because there is no
automatic changeover of parameters.
It is therefore recommended that the setup be
done in the following order:
1. Variant setting
2. Perform factory reset or set valid parameters.
6.4.1
ISDU
Name
Index
Device Variant
0x0055 (85)
Tab. 6-9:
Variant Configuration – ISDU
Device Variant
This parameter indicates which variant is currently set. The
device variant can be changed either with this parameter
or by using the IO-Link compatibility mode. If this
parameter is written, the device variant is not changed
immediately but instead after the device is restarted. If the
device variant is changed via the IO-Link compatibility
mode, the change in this parameter is visible immediately.
This parameter is not changed by a reset.
The following device variants are available:
Value
Meaning
0x0001 (1)
LSSC
0x0002 (2)
ADSS
0x0003 (3)
Condition Monitoring The device behaves in accordance with the Legacy-Smart-Sensor profile, but
Tab. 6-10: Overview of device variants
www.balluff.com
Subindex
Access
Length
0
R/W
2 bytes
Description
The device is compliant with the Legacy-Smart-Sensor profile.
The device is compliant with the AdSS-Smart-Sensor profile.
has a separate process data profile with Condition Monitoring information and
LSCC data.
Data Type
Data Storage
UINT16(ENUM)
No
english
Default
2 (ADSS)