Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BES M18EH1-L01C80B-S04G-L04 Konfigurationsanleitung Seite 191

Vorschau ausblenden Andere Handbücher für BES M18EH1-L01C80B-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
6
System Functions (continued)
6.7.4
Variant Dependence
The selection of the process data profile is variant-
dependent. A PD profile is assigned to each variant.
Device
Device ID
Variant
0x0001 (1)
0x020404
LSSC
(131100)
0x0002 (2)
0x020405
ADSS
(131101)
0x0003 (3)
0x020406
CCM
(131102)
Tab. 6-26: Process Data Information and Configuration – Variant
Dependency
PD Invalid
PD Inputs Invalid:
Input data (device-to-master) is marked as invalid if the
device status (see section 6.1 on page 78) of the device
is Failure. In all other states, replacement values for the
data are output for which the content cannot be output
correctly.
PD Outputs Invalid:
If a master sends the process data without explicitly
marking the data as valid by means of master command,
the data is not used in the device. The device operates
only with the last valid data. A special behavior can,
however, be defined for various pieces of data (e.g. BNI
can configure the values collected in this state by means of
parameters).
www.balluff.com
Possible PD variants
0x1E (30) Default
0x1F (31) Default
0x0F (15) Default
english
93

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis