System Commands

Command Value
Device Action
0x40 (64)
Teach Apply – Calculates the switching point for SP1, SP2.
0x41 (65)
Teach SP1 (ADSS: Teach SP) – Determines teach point 1 for setpoint 1 and calculates the
switching point.
0x42 (66)
Teach SP2 – Determines teach point 1 for setpoint 2 and calculates the switching point
0x43 (67)
Teach SP1 TP1 (ADSS: Teach TP1) – Determines teach point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2 (ADSS: Teach TP2) – Determines teach point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1 – Determines teach point 1 for setpoint 2
0x46 (70)
Teach SP2 TP2 – Determines teach point 2 for setpoint 2
0x47 (71)
Teach SP1 Start (ADSS: Teach SP Start) – Starts dynamic teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop (ADSS: Teach SP Stop) – Stops dynamic teach-in for setpoint 1 and calculates
the switching point.
0x49 (73)
Teach SP2 Start – Starts dynamic teach-in for setpoint 2
0x4A (74)
Teach SP2 Stop – Stops dynamic teach-in for setpoint 2 and calculates the switching point
0x4E (78)
Teach Reset – Any active teach-in process is interrupted, all temporarily stored values are reset.
0x4F (79)
Teach Cancel – Any active teach-in process is interrupted.
0x80 (128)
Device Reset – Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values (see section 6.3 on page 82).
0x81 (129)
Application Reset (see section 6.3 on page 82)
0x82 (130)
Reset Factory Settings (see section 6.3 on page 82)
0xA5 (165)
Maintenance Reset (see section 6.3 on page 82)
0xA6 (166)
Switching Counter Reset – Resets counter value and flags.
0xA7 (167)
Statistics Reset – Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg – Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop – Stops statistics operation completely.
0xAA (170)
Signal Speed Monitoring Reset – Resets the speed value and flags.
0xAC (172)
Statistics Start Moving Average – Starts the statistics of the moving average calculation.
0xAF (175)
Start Device Discovery
0xB1 (177)
Fine Adjust near – Adjusts the switching point one step closer to the sensor.
0xB2 (178)
Fine Adjust far – Adjusts the switching point one step further from the sensor.
0xC0 (192)
Set Reference Orientation – Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.
Tab. 3-7:
System Commands – Overview
www.balluff.com
english
21