Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BES M18EH1-L01C80B-S04G-L04 Konfigurationsanleitung Seite 154

Vorschau ausblenden Andere Handbücher für BES M18EH1-L01C80B-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
5
Secondary Device Functions (continued)
Statistics Data Output: Status
Bit
Meaning
position
0
Configured
1
Started Min/
Max/Avg
2
Started Moving
Average
3
Buffer Overflow
Event
4
Timeout Event
5
Reserved
6
Reserved
7
Reserved
Tab. 5-26: Statistics Data Output – Status
5.5.5
System Commands
Command Value Device Action
0xA7 (167)
Statistics Reset – Resets all output
parameters to 0 and all user
settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg –
Starts the statistics of the minimum
value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop – Stops statistics
operation completely.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving
average calculation.
Tab. 5-27: Basic statistics – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
56
english
Description
1 – all inputs are configured
1 – Min/Max/Avg running
1 – Moving Average
running
1 – buffer overflow
1 – the set time for the
minimum value/maximum
value/average calculation
has elapsed