Inductive sensors
6
System Functions (continued)
6.1.5
Detailed Device Status
Detailed Device Status indicates the currently pending
diagnosis messages (error, warning). For an event
overview, see section 3.6 on page 22.
It can be used to perform a more detailed error analysis or
to find the corresponding error source in the event of an
unexpected device status.
The length of the list varies dynamically depending on the
number of entries. Each entry in the list consists of the
EventQualifier and the EventCode and has a data length of
3 bytes. The total list can be queried via subindex 0,
individual entires with the corresponding subindex. Each of
the entries in the lists can only be called while the event is
pending.
Subindex
Object name
1
Error_Warning_1
2
Error_Warning_2
3
Error_Warning_3
4
Error_Warning_4
...
n
Error_Warning_n
Tab. 6-3:
Detailed Device Status
www.balluff.com
Data Type
Comment
3 byte
All bytes 0x00 (0): no error/warning
Byte 1: EventQualifier
3 byte
Byte 2, 3: EventCode
3 byte
3 byte
3 byte
english