Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BES M18EH1-L01C80B-S04G-L04 Konfigurationsanleitung Seite 170

Vorschau ausblenden Andere Handbücher für BES M18EH1-L01C80B-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
5
Secondary Device Functions (continued)
Alarm Enable
If the parameter is set (TRUE), the actual inclination
(degrees-difference or deviation) is compared with the
value of the alarm threshold. If the inclination is greater
than the threshold value, an event is created and sent.
Alarm Threshold
Threshold value of the inclination deviation for triggering an
event (see Fig. 5-10 on page 70).
Hysteresis taken into account, value is defined at
0° (upward) and −1° (downward).
Values: 1...180
Unit: Degrees (°)
Default_Value: 10°
Alarm Teaching Status
Bit
Description
0
Device has not yet been taught-in, no reference
orientation set, inclination value not available.
1
Device has been taught-in, reference orientation
is set, inclination value is available.
Tab. 5-54: Inclination and installation aid – Alarm Teaching Status (R)
Use system command 0xC0 for teaching-in and defining
reference orientation.
The device cannot calculate the inclination until
the reference position has been taught-in.
Alarm Inclination Status
Bit
Description
0
Device is in its taught-in position/orientation.
1
Device is incorrectly oriented, inclination is equal
to or greater than the threshold value.
Tab. 5-55: Inclination and installation aid – Alarm Inclination Status (R)
Reference Taught Position
X-, Y-, Z-coordinate values of the reference position set
(taught-in) by system command 0x0C.
Values: −16...+16, without vibrations, they should be in
the range −1...+1
Unit: g (9.81 m/s
)
2
Default: –
72
english
Inclination Deviation Value
Angle between the taught-in reference orientation and the
actual orientation:
Values: 0...180
Unit: Degrees (°)
5.12.5 System Commands
System Commands for teaching-in and defining the
reference orientation.
The device cannot calculate the inclination until
the reference position has been taught-in.
Command Value Device Action
0xC0 (192)
Set Reference Orientation – Sets
the reference orientation of the
actual position of the device.
Responses: ACK: command
successful, reference stored.
0x81 (129)
Application Reset – Resets the
inclination alarm configuration to the
default value of the firmware.
0x82 (130)
Reset Factory Settings – Resets the
inclination alarm configuration to the
default value of the firmware.
Tab. 5-56: Inclination and installation aid – System Commands
5.12.6 Events
Event
Event
Description
Code
Type
0x8CD0
Warning
Inclination
(36048)
alarm
► Check
installation.
Tab. 5-57: Inclination and installation aid – Events
This event shows that the device has lost its original
position (taking the threshold value into account). The
mounting of the device should be checked.
The device is still functional but the measured values may
be invalid because, e.g., the sensor turned and its teach
point was changed.
Device Status
1 –
Maintenance-
Required

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis