Inductive sensors
5
Secondary Device Functions (continued)
Switching Counter State
With Switching Counter State, the current status can be
read.
Value
Meaning
Description
0x00 (0) Not reached Value is less than Limit.
0x01 (1) reached
Value is greater than or equal to
Limit.
0x03 (3) exceeded
Value is greater than Limit.
0x08 (8) Startup
Startup delay currently running.
Delay
0xFF
Deactivated
Feature is deactivated.
(255)
Tab. 5-18: Switching Counter – Switching Counter State
Switching Counter Value
With Switching Counter Value, the current counter value
can be read.
5.4.5
System Commands
Command
Device Action
Value
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings – Resets writable
parameters to the default value.
0xA6 (166)
Switching Counter Reset – Resets
counter value and flags.
Tab. 5-19: Switching counter – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.4.6
Variant Dependence
The functionality is available in all variants.