Electric heater DE2XL
– The device should not be exposed to significant
dust emissions. Dust deposits on the heating el-
ement can cause a short-circuit when moisture is
also present.
14.3

Operating conditions

Under inadmissible operating conditions, the opera-
tional safety and the performance of the device may
not be sufficiently ensured. Inadmissible operating
conditions must therefore be avoided at all times.
When installing the device, the respective local
building, fire prevention and trade association regu-
lations must always be adhered to. Different ambient
conditions can pose different dangers.

Installation location

The device must not be connected to air ducts or
hoses.
The following safety clearances to flammable fume
parts must be strictly observed:
– Lateral: 0.60 m
– Outlet side: 2.00 m
– Inlet side: 0.20 m
– Upwards: 2.00 m
The following principles apply to the place of installa-
tion and to installing the device:
– The device is designed for the heating/ventilation
of closed rooms.
– The device must not be used in rooms and envi-
ronments with explosive atmospheres, combus-
tible liquids or gases.
– Do not use the device outdoors in damp weath-
er, in bathrooms or in other damp environments.
– The device must never be operated in the im-
mediate vicinity of bathtubs, showers, wash ba-
sins or swimming pools.
– The floors and ceilings at the place of installation
must be fire retardant.
24 / 34
– A sufficient safety clearance to flammable ob-
jects such as furniture, curtains and the like must
be maintained.
– The intake and outlet nozzles of the device must
not be narrowed or covered. The safety clear-
ances must be observed.
The device must not be covered with textiles and
the like (e.g. curtains).
– The device must be installed in an upright and
stable way.
– The mains voltage must correspond to the de-
tails on the rating plate.
– Extension cables must be selected according to
the performance data on the rating plate, in or-
der to prevent overload.
Keep extension cables as short as possible and
only ever use them when they are fully extend-
ed.
– The socket used must be earthed or protected
with an RC circuit-breaker when installed in-
doors.
– Only ever operate one device from one socket to
prevent overloading.
– Do not switch the device on automatically with a
timer or similar device.
– Monitor the device during operation and keep
children and pets at a safe distance.
The following principles apply to handling the device:
– Always handle the device with care. Never drop
the device, do not throw it or transport it unse-
cured.
– Only original spare parts or parts approved by
the manufacturer may be used.
– People under the influence of alcohol, drugs or
medication must not operate or maintain the de-
vice.
EN