10 IIoT-Funktionalität

10.3.2 Struktur

Name
Datentyp
name
string
order-id
string
fw-version
string
hw-version
string
mac
string
bus
number
failsafe
number
ip
string
snMask
string
gw
string
rotarys
array of numbers (3) Current position of the rotary switches:
ulPresent
boolean
usVoltage_mv
number
ulVoltage_mv
number
inputs
array of numbers (2) Real state of digital inputs.
output
array of numbers (2) Real State of digital outputs.
Handbuch EtherCAT®
Version 2.4 07/2023
Beschreibung
Device name
Ordering number
Firmware version
Hardware version
MAC address of the device
0 = No connection
1 = Connection with PLC
0 = Normal operation
1 = Outputs are in failsafe
IP address of the device
Subnet Mask
Default gateway
Array element 0 = x1
Array element 1 = x10
Array element 2 = x100
True, if there is a UL voltage supply
detected within valid range
US voltage supply in mV
UL voltage supply in mV (only
available for devices with UL supply)
Element 0 = 1 Byte: Port X1
Channel A to Port X4 Channel B
Element 0 = 1 Byte: Port X5
Channel A to Port X8 Channel B
Element 0 =1 Byte: Port X1
Channel A to port X4 Channel B
Element 0 = 1 Byte: Port X5
Channel A to port X8 Channel B
10.3 REST API
Beispiel
"0980 XSL 3912-
121-007D-00F"
"935 700 001"
"V.1.1.0.0 -
01.01.2021"
"V.1.00"
"3C B9 A6 F3 F6
05"
1
0
\[128,3\]
\[55,8\]
127