Attention!
Use the arrestor button only during operation with drill rig.
!
Its use during manual operation is not allowed.
If the machine stops for any reason or due to power failure,
immediately release the arrestor button by pressing the
ON/OFF switch.
If this button is not released, the tool may unintendedly
restart if the PRCD protective switch is operated and cause a
danger to the user.
Water Supply
The connector for the tool should be a GARDENA hose connector.
You can obtain it from your local dealer. Use only pure tap water.
If water comes out of the drainage hole at the gear neck, stop your work
and have the tool repaired by an authorised service shop.
Pay attention that neither persons in the working area nor the power
tool itself come into contact with the water that comes out.
Dust Exhaustion
Place the adapter with the ball valve onto the tool's
connector and turn into the direction of the arrow up to
the stop. Connect the tool to the water supply system or
a water pressure vessel using the push fit nipple.
Attention! The maximum water pressure should not
exceed 3 bars. In case of higher water pressure, a
pressure relieve valve must be used.
Dust which occurs during your work is hazardous to
health. That is why it is advisable to use a deduster
and to wear a dust mask on dry drilling. Place the
adapter for the dedusting unit onto the tool's
connector and turn into the direction of the arrow up
to the stop. As a suitable wet/dry deduster, our
DSS 35 M iP is available as add-on. The use of a
dedusting system is also a prerequisite for optimal
cutting performance of the bit (air cooling).