Storing The Electric Heat Exchanger Over Winter In Frost-Free Rooms; Storing The Electric Heat Exchanger Over Winter In Spaces At Risk Of Frost; Electric Heat Exchanger In A Vertical Position; Storing The Electric Heat Exchanger Over Winter In A Horizontal Position - Behncke EWT-80-40 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für EWT-80-40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Electric heat exchanger / Faults and corrections

5.1 Storing the electric heat exchanger over winter in frost-free rooms

5.2 Storing the electric heat exchanger over winter in spaces at risk of frost

5.2.1 Electric heat exchanger in a vertical position

Completely drain the electric heat exchanger via drain valves.

5.2.2 Storing the electric heat exchanger over winter in a horizontal position

Remove the electric heat exchanger in a horizontal position.
Rinse the electric heat exchanger to remove impurities and store in a dry place.
6

Faults and corrections

Fault
No output
The electric heat exchanger continues to heat up
even though the pool water circulation pump is
switched off
7

Technical illustrations

11
8

Declaration of conformity

CAUTION!
Procedures on technical systems by non-experts may lead to injuries and
material damage.
When shutting down in frost-free rooms, the electric heat exchanger must be
completely filled with water or completely drained.
CAUTION!
It is possible to store the heat exchanger over winter without frost damage if
the following steps are taken.
Close the shut-off valves in the water circuit.
(Shut-off valves must be installed in frost-free rooms)
Rinse and drain the electric heat exchanger and the connecting
pipework to the shut-off valves.
Investigate the possible causes
Is the electric heat exchanger connected to
the mains? Are the shut-off valves in the water
circuit open?
Is the electric heat exchanger completely filled
with water?
Has the electric heat exchanger been bled?
Is there sufficient water flow through the electric
heat exchanger (see technical data)?
Is the interlock between the pool water pump and
the electric heat exchanger active?