Electric heat exchanger / Safety

1.4 Sources of danger

1.5 Safety measures at the installation site

The electric heat exchanger must be installed in a frost-proof room with a stainless steel or plastic bracket.
Make sure that the maximum operating pressure of 300 kPa (3.0 bar) is not exceeded.
3
CAUTION!
The electric heat exchanger may be damaged.
If the maximum positive operating pressure of 300 kPa (3.0 bar) is exceeded,
the electric heat exchanger may leak.
CAUTION!
There is a risk of burning.
The connections and the electric heat exchanger can reach temperatures
of up to 100°C.
If the water flow is insufficient (< 1000 I/h), the electric heat exchanger may
seriously overheat.
The installation of a flow monitor as an additional safety device is generally
recommended.
CAUTION!
The electric heat exchanger may be damaged.
Contact corrosion is a risk due to water dripping onto the outer skin or when
metal parts are washed into the electric heat exchanger.
CAUTION!
The electric heat exchanger and its surroundings may be damaged.
Check the electric heat exchanger and its connections for leaks and visible
damage at least once a week while the pool is in use.
CAUTION!
There is a risk of fire.
If the water flow is insufficient (< 1000 I/h), the electric heat exchanger may
seriously overheat.
Do not store flammable materials nearby.
The installation of a flow monitor as an additional safety device is generally
recommended.
This also prevents the heating resistor from burning out when the water stops.