Technical data

3-phase mains connection 400 V

Rated data

3-phase mains connection 400 V
Rated data
The output currents apply to these operating conditions:
• At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C.
• At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter
Rated power
Mains voltage range
Rated mains current
with mains choke
Apparent output power
Output current
2 kHz
4 kHz
8 kHz
16 kHz
Power loss
4 kHz
8 kHz
at controller inhibit
Overcurrent cycle 180 s
Max. output current
Overload time
Recovery time
Max. output current dur-
ing the recovery time
Overcurrent cycle 15 s
Max. output current
Overload time
Recovery time
Max. output current dur-
ing the recovery time
Cyclic mains switching
Brake chopper
Max. output current
Min. brake resistance
Max. motor cable length
shielded
without EMC category
Category C2
Weight
60
I55AE355F
kW
A
kVA
A
A
A
A
W
1210
W
1580
W
A
s
s
A
A
s
s
A
A
Ω
m
m
kg
55
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
99
75
110
110
110
73.4
30
165
60
120
83
220
3
12
83
1 time per minute
166
4.7
100
20
24
I55AE375F
75
135
100
150
150
150
100
1640
2140
30
225
60
120
113
300
3
12
113
166
4.7

Werbung