6.

Configuration

The configuration can be selected in the "Mode" menu
when the battery is connected, or via the
key if the battery is not connected ("
connected
" appears on the TFT display).
The procedure to be followed when the battery is
disconnected:
1. Switch on the BAT 645 (fig. 1, item 1).
 The red LED flashes (fig. 1, item 7).
 "
No battery connected
display.
2. Press
.
 The configuration menu is displayed.
3. Select menu item with
4. Press
.
 The menu item selected is opened.
i
exits the configuration menu.
6.1
Parameters
The "Parameters" menu can be used to enter
customer-specific parameters for 12 V and 24 V
batteries in the "Buffer" and "Back-up" modes and to
select the length of the connected charging cable.
1. Select the "Parameters" configuration menu.
2. Press
.
 "Edit values" is displayed.
3. Select parameter set with
4. Press
.
 The parameter set is displayed.
Robert Bosch GmbH
selection
No battery
" appears on the TFT
or
.
or
.
Configuration | BAT 645 | 21 |
6.1.1

Buffer/back-up mode parameters

!
Incorrect parameter values (excessively high
values) may destroy the battery and the vehicle.
When operating an LFP battery in buffer mode, the
instructions of the battery manufacturer must be
observed.
The "Buffer/back-up mode" parameter set displays
e.g. the following.
The following parameters can be selected in buffer
mode:
Storage battery
Voltage
12 V
11 V – 14.2 V
24 V
22 V – 28.4 V
The following parameters can be selected in back-up
mode:
Storage battery
Voltage
12 V
11 V – 14.2 V
24 V
22 V – 28.4 V
1. Select parameter (voltage) with
2. Press
.
 The next parameter (current) is activated.
3. Select parameter with
4. Press
.
5. Press
.
6. Connect battery.
7. Press
.
 Battery voltage is displayed.
8. Select "Buffer mode" or "Back-up mode".
"
Buffer/back-up mode is activated with the selected
parameters.
6.1.2
Parameters of charging cable
!
The correct length of charging cable must be
selected as otherwise incorrect values could be
displayed when charging the battery.
1. Select charging cable length with
2. Press
.
"
The selected charging cable length is used when
charging.
!
The charging cables are not to be modified.
en
Power
3 A – 45 A
3 A – 22 A
Power
3 A – 20 A
3 A – 20 A
or
.
or
.
or
.
|
1 689 989 233