Herunterladen Inhalt Inhalt Diese Seite drucken

Flue Connection - HWAM Figaro gas Installations- Und Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Figaro gas:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Clearance requirements
If the appliance has to be located in an opening, the minimum clearance from non-combustible
materials is shown on drawing C.
The stove must be located at least 150 mm from any combustible materials.
A combustible shelf may be fi tted over the appliance, provided that in the case of a 150 mm or
less deep shelf, there is at least 150 mm clearance above the top of the stove. The shelf depth
may increase (drawing C, measurement a) at the same rate as the increase in clearance (drawing
C, measurement b); i.e. a shelf depth of 200 mm would require a clearance of 200 mm
Hearth
The stove must stand on a fi reproof hearth.
To comply with the Building Regulations issued by the Department of the Environment, the fol-
lowing points should be noted when choosing a hearth:
i) the hearth must be made of non-combustible material of thickness 12 mm minimum
ii) the hearth must not be capable of inadvertent covering by a carpet or rug. This should be
achieved by either:
a) the hearth being 50 mm (2") above the level of the room fl oor
b) a fender or kerb around the edge of the hearth to a height of at least 50 mm (2") above the
fl oor.

Flue connection

Balanced Flue Connection
The Carmen and Figaro Balanced Flue is approved to be vented to the outside through an
adjacent exterior wall. The venting system must comprise of the specifi ed venting components
listed below.
Carmen gas and Figaro gas are approved to the following two combinations of fl ue components:
Docherty New Vent LTD:
Rear Flue Parts:
1 No. Connector Pipe
2 No. 90° Bend
1 No. Telescopic Pipe
1 No. Termination Cowl
The fl ue components listed in the above table have be assembled as shown on drawing D1 and
D2.
To join the fl ue sections, adopt the following. The crimped section of the fl ue should always face
outward or (in the case of a top fl ue stove) vertical.
In applications using the telescopic fl ue, the joints of the fl ue pipe must be sealed before the
fl ue is put into the wall. It is recommended that this seal be made with a high temperature tape,
such as aluminium tape.
Part No. CB35145
Part No. CB35845
Part No. CB35645
Part No. CB35545
Metaloterm Ontop:
Top Flue Parts:
1 No. Element 100 cm
1 No. Elbow 87°
1 No. Wall plate
2 No. locking band
1 No. Horizontal terminal
32
US 100
USB 90
USMP
USKB
USDHCE

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Carmen gas