Herunterladen Inhalt Inhalt Diese Seite drucken

Control Options; Technical Information - HWAM Figaro gas Installations- Und Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Figaro gas:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Control options

Manual: Variable rotary gas control with integrated Piezo Ignition, Permanent pilot facility and
fl ame failure safety device
Remote: Integrated Ignition, Permanent pilot facility and fl ame failure safety device, battery
operated hand held.

Technical information

Carmen, Balanced Flue
Gas
Heat Input (gross)
Supply pressure
Burner pressure
Gas rate
Injector marking
Country of use
Carmen, Natural Draught
Gas
Heat Input (gross)
Supply pressure
Burner pressure
Gas rate
Injector marking
Country of use
I2H
I2L
G20
G25
7.7 kW
7.3 kW
20 mbar
25 mbar
17.9 mbar
22.1 mbar
0.73 m
3
/hr
0.80 m
560
560
DK, AT, FI,
NL
IT, IE, PT,
ES, SE & GB
I2H
I2L
G20
G25
8.3 kW
7.7 kW
20 mbar
25 mbar
17.9 mbar
22.1 mbar
3
0.80 m
/hr
0.86 m
560
560
DK, AT, FI,
NL
IT, IE, PT,
ES, SE & GB
Natural
I2E/12E+
G20
G25
7.7 kW
7.3 kW
20 mbar
25 mbar
17.9 mbar
22.1 mbar
3
/hr
0.73 m
3
/hr
0.80 m
560
BE & FR
Natural
I2E/12E+
G20
G25
8.3 kW
7.7 kW
20 mbar
25 mbar
17.9 mbar
22.1 mbar
3
3
/hr
0.80 m
/hr
0.86 m
560
BE & FR
29
English
LPG
I2ELL
LPG I3P
G25
G31
6.3 kW
6.2 kW
20 mbar
37 mbar
17.9 mbar
36.6 mbar
3
/hr
0.70 m
3
/hr
0.23 m
560
200
DE
BE, FR,
IE, IT, PT
ES & GB
LPG
I2ELL
LPG I3P
G25
G31
7.0 kW
6.8 kW
20 mbar
37 mbar
17.9 mbar
36.6 mbar
3
3
/hr
0.78 m
/hr
0.25 m
560
200
DE
BE, FR,
IE, IT, PT
ES & GB
3
/hr
3
/hr

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Carmen gas

Inhaltsverzeichnis