Herunterladen Inhalt Inhalt Diese Seite drucken

Master/Slave-Operation; Connection With The Mains - EuroLite LED Panel RGB DMX 230 V Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.

Master/Slave-Operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LED PANEL you can find an XLR-jack and an XLR-plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a stereo shielded cable. Connect
the OUT-jack with the IN-plug of the next device.
Set DIP Switch 10 to 0 in order to determine the Master device, then choose the desired mode. (see
OPERATION)

Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
International
L
N
16/35
resistor
51928735_V_1_0.DOC

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis