DMM measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest in-
dicated point)). The accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a
relative humidity of less than 75 %, non-condensing.
Direct voltage range, overload protection 600 V
Range
200 mV
2 V
20 V
200 V
600 V
Alternate voltage range, overload protection 600 V
Area (50-60 Hz)
2 V
20 V
200 V
600 V
Resistance range
Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Acoustic Continuity tester
Diode test voltage
44
Accuracy
±(0,5% + 3)
±(1% + 3)
Accuracy
±(1% + 5)
±(1,5% + 10)
Accuracy
±(0,8% + 5)
±(1,2% + 3)
±(2% + 5)
±(5% + 8)
<150 Ω
1.5V/DC; test current: max. 1 mA
Resolution
0,1 mV
1 mV
10 mV
100 mV
1 V
Resolution
1 mV
10 mV
100 mV
1 V
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ