G
VoltAge tester "Vc-63"
item no. 1313885
ntenDeD use
The 2pole voltage tester can be used to measure and display AC and DC voltages in an electrical
low-voltage circuit. The product also has an acoustic and visual circuit indicator as well as an RCD
test. Power is supplied by two batteries of type AAA/Micro included in the delivery.
The voltage tester complies with the standard for two-pole voltage testers of 12 - 690 V/CAT III
1000 V, CAT IV 600 V according to EN 61243-3:2010/EN 60529 as well as protection class IP64
(dust and splashed water). The product is suitable for use in dry or damp conditions. Use during rain
or other precipitation is not permitted. The voltage tester is designed for use by electrically skilled
persons using personal protective equipment.
The measuring instrument must not be operated when the battery compartment is open.
Measuring under adverse ambient conditions such as dust and flammable gases, vapours or
solvents is not permitted.
Always observe the safety instructions and all other information included in these operating instruc-
tions.
This product complies with the applicable national and European requirements. All names of com-
panies and products are the trademarks of the respective owners. All rights reserved.
pAckAge contents
• Voltage tester
• 2x batteries Micro/AAA
• 2x plastic protective sleeves
• 2x 4mm-adapter for unscrewing the measuring probes
• Operating instructions
explAnAtion of symBols
T he lightning flash symbol in a triangle warns against the risk of an electric shock or
interference with the electrical safety of the device
A n exclamation mark inside a triangle refers to important notes in the operating instruc-
tions.
T he arrow symbol indicates special information and advice on operating the device.

sAfety instructions

the warranty will expire in case of any damage caused by the failure to follow
these operating instructions! we assume no liability for any resulting consequen-
tial damage!
we assume no liability for any damage to property or personal injuries caused by
improper use or non-compliance with the safety instructions! the warranty will be
void in such cases.
• T he unauthorised conversion and/or modification of the product is not permitted for
safety and approval reasons (CE). Do not disassemble the product.
• T his product is not a toy. Therefore, be especially careful when children are around.
Use the product where it is out of the reach of children.
• N ever use the product immediately after it has been taken from a cold room to a warm
one. The condensation that forms can ruin the product under certain circumstances.
• A void the following adverse conditions at the location of installation and during trans-
port:
- Extreme cold or heat, direct sunlight
- Dust or flammable gases, fumes or solvents
- Strong impacts, blows
• D o not leave packaging material carelessly lying around, since it could become a
dangerous plaything for children.
• H andle the product with care; it can be damaged by impacts, blows, or accidental falls,
even from a low height.
• N ever touch the measuring probes or a measuring point during the measuring process.
There is the risk of an electrical shock.
• N ever touch areas outside of the marked handling area during a measurement.
• D o not use in the immediate proximity of strong magnetic or electromagnetic fields or
transmission aerials. These can affect the measurement.
• P rior to and after each measurement, check your instrument and the measuring leads
for damage. Never take any measurements if the protective insulation is defective or
the measuring instrument is damaged otherwise.
• B e especially careful when dealing with voltages higher than 50 V/AC or 75 V/DC. Even
at such voltages you can get a life-threatening electric shock if you come into contact
with live electrical wires.
• T he measuring instrument is suitable for use in dry or damp conditions. Avoid use in a
wet environment.
• A lways ensure that the measuring probes are perfectly clean. Dirty or even corroded
measuring probes can lead to an incorrect measurement.
• T he measuring probes must only be touched at the handles provided for this purpose.
Version 09/15
Otherwise, there is danger of an electric shock.
• N ever exceed the highest permissible voltage values. If the stated values are
exceeded, the product may become damaged and a fatal hazard exists. (See chapter
"Technical Data").
• T he recovery time as specified in Technical Data must always be adhered to. Other-
wise, the product could be damaged.
• T he voltage values specified are nominal voltages.
• I f the neutral wire (N) or the earth wire (PE) is interrupted, no reading is shown.
• U se the measuring instrument only within the allowed ambient conditions (see Chapter
"Technical Data").
• A lways attach the measuring probe cover if you are no longer using the device.
• K eep the measuring instrument in a dry, dust-proof place when not in use.
• W hen using the voltage tester in the measurement category CAT III and CAT IV, it
is recommended to attach the plastic protective sleeves to the measuring probe to
decrease the exposed contact tip length of the probe. This reduces the risk of possible
short circuit during testing.
• C AT I
• C AT II M easurement Category II is applicable for measuring circuits of electrical and
• C AT III M easurement category III for measuring building installations (e.g., mains
• C AT IV M easurement category IV for measuring the source of low-voltage installa-
generAl BAttery instructions
• B atteries should be kept out of the reach of children.
• D o not leave batteries lying around in the open; there is a risk of them being swallowed by child-
ren or pets. If they are swallowed, consult a doctor immediately.
• L eaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable
protective gloves.
• B atteries must not be short-circuited, opened or thrown into fire. There is a risk of explosion.
• M ake sure that the polarity is correct when inserting the batteries (pay attention to plus/+ and
minus/-).
Description of symBols
V Ac Dc
12/24/36/50/120/230/400/690
k Ω
Hz
M easurement category I for measuring electrical and electronic devices that
are not directly supplied with mains voltage (e.g., battery-operated devices, etc.)
electronic equipment that is directly supplied with the mains voltage via a
power plug.
sockets or sub-distributors).
tions (e.g., main distribution, main transfer point of the utility company) and
outdoors.
Alternating Current (AC)
V/AC: Alternating voltage
V/DC: Direct current
Display of rated voltage range in volt (V)
Direct current positive potential DC
Direct current negative potential DC
Electrical resistance in kilo-ohm
Electrical frequency (Hertz)
single-pole phase display 100 - 690 V as well as warning for
hazardous voltage (>50 V/AC, >120 V/DC)
Operation also possible with flat batteries or without batteries
Continuity test symbol
Battery symbol for data of used battery
Conformity symbol, CE-approved
Apparatus and equipment for live works.
Personal protection equipment required
Protection class 2 (double or reinforced insulation/protective