9.3.2 Flame baffle plate

On delivery the flame baffle plate (see Appendix 2, fig. 5) is located in the top section of the appliance.
In case of maintenance to the appliance, the flame baffle plate has to be removed.
To do this proceed as follows:
Ø
Take hold of the flame baffle plate and push the right side upwards.
Ø
Slide the flame baffle plate over the ridge to the right.
Ø
Lower the left side of the flame baffle plate and remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
The stainless steel profile must be placed at the front with the screw heads facing the top (see Appendix 2, fig. 5).
!Caution

9.4 Adjusting the door / Replacing door seal

Check the closing of the door during installation or maintenance.
To do this proceed as follows:
Ø
Check the sealing of the door by placing a sheet of paper between the door and the fire. After closing the door, it
should not be possible to pull out the sheet of paper easily. Check the outside of the fire.

9.5 Supplementary installation instructions per appliance

9.5.1 Ivar 5-01, Low, Aste 5 and Soren 5

9.5.1.1 Outside air connection

Outside air connections are available for these appliances as accessories. Assembly always takes place at the
bottom of the appliance.
When installing an RS appliance, the outdoor air-connection is pre-mounted at delivery. If so, observe the steps
!Caution
described under the heading 'Outdoor air connection pre-mounted'.
Outdoor air connection not pre-mounted:
In case of these appliances, exhaust is only possible via the rear.
When mounting the outside air connection, please proceed as follows (see Appendix 2, fig. 9a + 9b):
Ø
Loosen the 5 bolts that are pre-mounted on the outside air connection.
Ø
Bring the outside air connection against the plate on the bottom of the appliance.
Ø
Then re-tighten the 5 bolts.
Ø
Fasten the tray for the benefit of the rear connection with 4 bolts.
Ø
Connect the flexible hose to the round 'pipe opening' of the above-mentioned tray.
The flexible hose can only be fed from the rear.
The round pipe opening for the benefit of the lower connection is not needed during installation and should be
Caution!
disposed of responsibly.
Outdoor air connection pre-mounted:
Ø
Connect the flexible hose (Ø 80 mm) to the round 'pipe mouth' of the outdoor air connection.
In the case of an RS appliance, you are dealing with a fully closed system. This means that you must always ensure
!Caution
an airtight connection of the flexible hose to the round 'pipe mouth' by using heat resistant sealant.
The flexible hose can only be supplied from the rear. If you want to disassemble the outdoor air connection, you
!Caution
should perform the above-mentioned steps in reverse order.
40
I N S T A L LA T I ON M A N U A L