9.5.1.2 Assembly/disassembly of glass pane in door

Avoid damage when removing/fitting the glass pane.
!Caution
Avoid/remove fingerprints on the glass pane(s) as they will burn into the glass.
Use the supplied glass pane cleaner to remove fingerprints from the glass pane(s).
!Tip
To remove the glass pane and then remount it in the door, please follow the instructions below
(see Appendix 2, fig. 10).
Disassembly of glass pane in door:
Ø
Open the door.
Ø
Lift out the door by sliding it upwards.
Ø
Place the door on a flat surface.
Ø
Unscrew the 4 bolts that hold the clamps.
Ø
Lift out the glass pane. The pane seal is also taken out.
Assembly of glass pane in door:
Ø
Mount the glass pane and place back the door by performing the steps for disassembling the glass pane in
reverse order.
Do not fasten the bolts too tight to avoid breaking off and/or stripping: overtightening will cause breakage.
!Caution
Place the glass pane (including new pane seal) with the logo to the bottom right.

9.5.1.3 Replacing door seal

Proceed as follows when replacing the door seal:
Ø
Remove the door seal by taking it out of the integrated groove.
Ø
Remove excess kit residues from the door seal groove.
Ø
Use a heat-resistant kit to apply a new layer of kit in the groove.
Ø
Place the new door seal.
Regularly check the sealing in the case of an RS appliance, replace if necessary to ensure RS.
!Caution
9.5.1.4 Heat shield (optional)
When using a heat shield and an isulated tube, it is possible to place the appliance closer to the wall. This heat
shield is optionally available via your supplier.
A heat shield can only be placed if the flue gas discharge on the top side of the appliance has been connected.
Caution!
Proceed as follows:
Attaching the guard plate to the appliance:
Ø
Loosen the 4 pre-mounted bolts at the back of the appliance by a few turns
Ø
Place the plate against the back of the appliance.
Ø
Re-tighten the 4 bolts.

9.5.2 Ivar 5, High

9.5.2.1 Outside air connection

Outside air connections are available for these appliances as accessories. Assembly always takes place at the
bottom of the appliance. Connection is possible via both the rear and bottom side.
When installing an RS appliance, the outdoor air-connection is pre-mounted at delivery. If so, observe the steps
!Caution
described under the heading 'Outdoor air connection pre-mounted'
Outdoor air connection not pre-mounted:
When mounting the outside air connection, please proceed as follows (see Appendix 2, fig. 9a/9b and 11a/11b):
Ø
Loosen the 5 bolts that are pre-mounted on the outside air connection.
Ø
Bring the outside air connection against the plate on the bottom of the appliance.
Ø
Then re-tighten the 5 bolts.
Ø
Now decide whether you will be using a rear or bottom connection.
41