IN S TA LLA TION M A N U A L
9.5.2.4 Heat shield (optional)
When using a heat shield and an isulated tube, it is possible to place the appliance closer to the wall. This heat
shield is optionally available via your supplier.
A heat shield can only be placed if the flue gas discharge on the top side of the appliance has been connected.
Caution!
Proceed as follows:
Attaching the guard plate to the appliance:
Ø
Loosen the 4 pre-mounted bolts at the back of the appliance by a few turns
Ø
Place the plate against the back of the appliance.
Ø
Re-tighten the 4 bolts.
9.5.3 Ivar 5, Store

9.5.3.1 Outside air connection

Outside air connections are available for these appliances as accessories. Assembly always takes place at the
bottom of the appliance.
When installing an RS appliance, the outdoor air-connection is pre-mounted at delivery. If so, observe the steps
!Caution
described under the heading 'Outdoor air connection pre-mounted'.
Outdoor air connection not pre-mounted:
When mounting the outside air connection, please proceed as follows (see Appendix 2, fig. 12a + 12b):
Ø
Unscrew the 4 screws of the reflection plate and remove the plate. The reflection plate is located under the air
slide and protects the wood stacked below the stove against the high temperatures created in the appliance.
Ø
Break out the plate at the back of the appliance with a hammer.
Ø
Loosen the 5 bolts that are pre-mounted on the outside air connection.
Ø
Bring the outside air connection against the plate on the bottom of the appliance.
Ø
Then re-tighten the 5 bolts.
Ø
Fasten the tray for the benefit of the rear connection with 4 bolts.
Ø
Connect the flexible hose to the round 'pipe opening' of the above-mentioned tray.
Always place back the reflection plate!.
CAUTION!
Outdoor air connection pre-mounted:
Ø
Connect the flexible hose (Ø 80 mm) to the round 'pipe mouth' of the outdoor air connection.
In the case of an RS appliance, you are dealing with a fully closed system. This means that you must always ensure
!Caution
an airtight connection of the flexible hose to the round 'pipe mouth' by using heat resistant sealant.
If you want to disassemble the outdoor air connection, you should perform the above-mentioned steps in reverse
order.

9.5.3.2 Assembly/disassembly of glass pane in door

Avoid damage when removing/fitting the glass pane.
!Caution
Avoid/remove fingerprints on the glass pane(s) as they will burn into the glass.
Use the supplied glass pane cleaner to remove fingerprints from the glass pane(s).
!Tip
To remove the glass pane and then remount it in the door, please follow the instructions below
(see Appendix 2, fig. 10).
Disassembly of glass pane in door:
Ø
Open the door.
Ø
Lift out the door by sliding it upwards.
Ø
Place the door on a flat surface.
Ø
Unscrew the 4 bolts that hold the clamps.
Ø
Lift out the glass pane. The pane seal is also taken out.
43