- This function is likely to be used more to prevent battery pack from being
overheating rather than normal charge completion
3-4. MAX CAPACITY
- This is to set your wanted discharge percentage against the selected battery
capacity.
- If "OFF" is set, this max capacity function is not activated.
- If battery capacity is 3000mAh and if you set 10% out of the total max capacity, the
charger should stop discharging at 300mAh
3-5. MATCHED VOLT
- This is only for NICD and NIMH batteries.
- This mode should be activated when it moves to "MATCH" mode from
DISCHARGE PROCESS
- To activate this mode, balancing cable MUST be connected to the balancing port
of the charger.
- Discharge to selected voltages with selected discharge currents and match each
cell voltage.
- If the discharge cut-off voltage is set to the same voltage as the match voltage, the
discharge current will be reduced when the cut-off voltage
is reached, to hold the constant voltage at the match/cut-off voltage level.
High current competition NiMH batteries should be matched before charging.
Matching the batteries does increase the life time of the battery.