10. Technical data

Dimensions H x W x D (mm) 134 x 81 x 33
Weight
Operating voltage
Ambient temperature
Protection class
Accuracy
Running reserve
Ladedauer
Shortest switching period:
- daily program
- weekly program
Programmable every
Switching preselection
Switching state display and operating modes:
Heating mode
Service-water
Automatic mode
Continuous mode
Holiday mode
Type of installation
Connection type
Temperature
Heating control range
Protection against freezing TEMP 1 setting
Differential temperature gap
Degree of protection
GB
approx. 200g
System voltage
- 5 °C to + 45 °C
II
typ 2,5 s/day at + 25 °C
5 h
24 h
1 h
1 h
15 min
yes
Flame symbol
Symbol
AUTO
TEMP1, TEMP 2 or TEMP 3
HOLIDAY
Surface-mounted
Screw-type terminals, each 2,5 mm
+ 5 °C to + 35 °C
(factory setting: 5°C)
+ / - 0,25 at 0,4 K *
IP 20

11. Questions and Answers

Questions:
The unit does not work
– no display
– no heating operation
Answers:
Check the connection
Press RES. if necessary
Questions:
It is not possible to set the value for the
temperature level
Answers:
Select values within the setting range see Abschnitt 6.1 ff
Questions:
The wrong key has been pressed or
incorrect values have been entered during
programming.
Answers:
Cancel the operation:
Repeat the complete programming sequence.

12. Cleaning and maintenance

2
Use a dry cloth to clean the unit.
Never use any caustic cleaning agents.
49
see Section 3.1
see Section 7.4
GB