Herunterladen Inhalt Inhalt Diese Seite drucken

Door And Filter - Candy CS C7LF-S Handbuch

Vorschau ausblenden Andere Handbücher für CS C7LF-S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
6.

DOOR and FILTER

Pull on handle to open the door.
To restart the dryer, close the door and press
Start / Pause button.
WARNING! When the tumble dryer is in
use the drum and door may be VERY HOT.
Filter
IMPORTANT: To maintain the efficiency of
the dryer check that the fluff filter is clean
before each drying cycle.
1.
P u l l t h e f i l t e r
upwards.
2.
Open filter as shown.
3.
Gently remove lint
using a soft brush or
your fingertips.
4.
S n a p t h e f i l t e r
together and push
back into place.
Filter Care Indicator
Lights when the filter needs cleaning.
If the laundry is not drying check that the filter
is not clogged.
IF YOU CLEAN FILTER UNDER
WATER, REMEMBER TO DRY IT.
WARNING! If you open the door mid
cycle, before the cool-down cycle has
completed, he handle may be hot. Please se
t
e
xtreme caution when attempting to empty
the water reservoir during the cycle.
1
2
u
11
To Remove the Condenser
1.
Remove the kickplate
2.
Turn the two locking
levers anti-clockwise
and pull out the
condenser.
3.Pull out the condenser
unit.
4.
Gently remove any
dust or fluff with a
cloth, then wash the
unit by holding it under
a running tap turning it
so that water flows
between the plates, to
remove any dust or
fluff.
5.Check the gasket
p o s i t i o n
a f t e r
c l e a n i n g . F i t t h e
gasket in to the groove
if it is misaligned.
6.
Refit the condenser
ensuring it is in the
c o r r e c t w a y ( a s
i n d i c a t e d b y t h e
arrow) and pushed
firmly into place. Lock
the two levers by
t u r n i n g
t h e m
clockwise.
Be sure
that condenser unit
fixed to the basement
tightly.
7.
Refit the kickplate.
.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis