Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
Component
Action
Housing
Clean the outside of
the machine with a
non-aggressive
detergent.
Clean the inside of the
machine using an
industrial vacuum
cleaner and remove
dust from the filter
compartment.
Spark
Clean the spark
arrester,
arrester, the ioniser,
ioniser,
the collector and the
collector and
final filter. Check all
final filter
filters for damages.
Extraction fan
Check the extraction
fan and the extraction
fan housing for
encrusted particles.
Clean if necessary.
Check sealing material
of the extraction fan.
Replace if necessary.
Mains cord
Check the mains cord
for damage. Repair or
replace if necessary.
Activated
Check for damage,
carbon filter
clogging and
saturation. Replace if
necessary.
a.
Cleaning frequency depends on welding process and intensity of use.
6.2

Filter cleaning

ATTENTION!
Always wear face mask and gloves during filter
exchange/cleaning.
Clean the filters:
- when the ioniser and/or the collector start making a sputtering
noise (high voltage indicator starts blinking or fully
extinguishes); or
- when the airflow is reduced to the point that extraction
performance is no longer satisfactory; or
- when damaged
Since the nature and the degree of saturation strongly depend
on for example the composition of the welding fumes, the
humidity and the intensity of use, etc. you must learn from
experience when to clean the filters. However, the filters should
be cleaned regularly (every 2 weeks up to every 2 months).
To clean the filters proceed as follows.
6.2.1 Dismounting the filters
Fig. 6.1
Turn off the machine and disconnect it from the mains.
Loosen the thumb nut (A) and remove the filter cover (B).
0507250020/010513/F Mobiflex 300-E
Frequency: every X months
X=
X=3
X=6
X=12
a
0,5-2
X [*]
X [*]
X [*]
X
X
Before
every
use X
[*]
X
A
B
Fig. 6.1: Open filter cover
Fig. 6.2
Lift the complete filter module (C) using the handle (A) on
the door (B) until the filter module locks in service position.
C
Fig. 6.2: Lift filters
Fig. 6.3
Open the door and subsequently remove the spark arrester
(C), the ioniser (D), the collector (B) and the final filter (A).
A
Fig. 6.3: Removal of filters
A
B
B
4
3
1
2
C
EN - 14