Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Voltage Versions And Electrical Data; Plumbing; Cold Water Connection - Miele PDW 909 SOM Installationsplan

Wasch-trocken-säule
Vorschau ausblenden Andere Handbücher für PDW 909 SOM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en - Technical data

Voltage versions and electrical data

3 AC 400/440/480 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
3 AC 230 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
3N AC 400 V EL
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section

Plumbing

Cold water connection

Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose included in scope of supply

Hot water connection

Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied
50
Washing machine
3 AC 400/440/480
60 Hz
3 x 10 A
Type B
5,25/6,3/7,45 kW
4 x 1,5 mm²
Washing machine
3 AC 230 V
60 Hz
3 x 20 A
Type B
8,2
4 x 2,5 mm²
Washing machine
3N AC 400 V
60 Hz
3 x 16 A
Type B
8,2 kW
5 x 1,5 mm²
Tumble dryer
3 AC 400/440/480 V
60 Hz
3 × 10 A
Type B
4,6/6,4/5,5 kW
1,5 mm²
Tumble dryer
3 AC 230 V
50/60 Hz
3 × 25 A
Type B
8,2 kW
1,5 mm²
Tumble dryer
3N AC 400 V
50/60 Hz
3 × 16 A
Type B
8,2 kW
1,5 mm²
100 - 1000 kPa (1 - 10 bar)
10 l/min
3/4"
1550 mm
70 °C
100 - 1000 kPa (1 - 10 bar)
10 l/min
3/4 "
1550 mm

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis