Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Voltage Versions And Electrical Data - Miele PWM 920 Installationsplan

Gewerbliche waschmaschine
Vorschau ausblenden Andere Handbücher für PWM 920:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Technical data

Voltage versions and electrical data

3N AC 400 V, 50/60 Hz, EL A01Z
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3 AC 230 V, 50/60 Hz, EL B04Z
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3 AC 400 V, 50/60 Hz, EL B11Z
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3 AC 440/480 V, 60 Hz, EL B14Z
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3 AC 230 V, 50/60 Hz, EL F04ZY
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
en - PWM 920
3N AC 400V 50/60Hz
50/60 Hz
35 A
19 kW
6 mm²
3 AC 230V 50/60Hz
50/60 Hz
50 A
19 kW
10 mm²
3 AC 400V 50/60Hz
50/60 Hz
35 A
19 kW
6 mm²
3 AC 440/480V 60Hz
60 Hz
35 A
22,5 kW / 19,5 kW
6 mm²
3 AC 230V 50/60Hz
50/60 Hz
50 A
19 kW
10 mm²
35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pwm 920 el dv dd wpPwm 920 el dv ddPwm 920 el dv dd hsPwm 920 el dv dd stPwm 920 el/rh

Inhaltsverzeichnis