Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Voltage Versions And Electrical Data; Connection For Equipotential Bonding - Miele PW 6241 EL/RH Installationsplan

Gewerbliche waschmaschine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Voltage versions and electrical data

Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Miele recommends connecting the machine via a wall socket with an all-pole means of deactivation and interlock in accordance with
IEC 60309 and IEC 60947 so that electrical safety checks can be carried out easily.
For hard-wired machines, an isolator in accordance with IEC 60947 must be installed.
The wall socket or isolator must remain accessible at all times once the machine has been installed.
To increase safety, Miele recommends installation of a residual current device (RCD). Only use residual current devices that are
sensitive to universal current (type B).

Connection for equipotential bonding

Connection with male thread (machine)
Size of washers and nuts
An equipotential bond with good contact connection must always be provided in accordance with all national and local regulations.
en - Technical data
Standard:
3 AC 220 - 240 V
50 Hz
25 kW
3 x 80 A
4 x 25 mm²
M40 x 1,5 mm
Standard:
3 AC 220-240V
50 Hz
25 kW
3 x 80 A
4 x 25 mm²
M40 x 1,5 mm
Standard:
3N AC 380–415 V
50 Hz
25 kW
3 x 50 A
5 x 16 mm²
M16 x 1,5 mm
Standard:
3N AC 380-415V
50 Hz
10,5 kW
3 x16 A
5 x 1,5 mm²
M16 x 1,5 mm
10 mm x 30 mm (3/8" x 1 3/16")
Convertible to:
3 AC 208 V
60 Hz
20 kW
3 x 70 A
4 x 25 mm²
M40 x 1,5 mm
Convertible to:
3 AC 220-240V
60 Hz
25 kW
3 x 80 A
4 x 25 mm²
M40 x 1,5 mm
Convertible to:
3N AC 380-415 V
60 Hz
25 kW
3 x 50 A
5 x 16 mm²
M16 x 1,5 mm
Convertible to:
3N AC 380-415V
60 Hz
10,5 kW
3 x16 A
5 x 1,5 mm²
M16 x 1,5 mm
3 AC 440V
60 Hz
25 kW
3 x 50 A
5 x 16mm²
M16 x 1,5 mm
M 10
33