Pedestrian automatic closing time adjustment
(se = 0 pedestrian automatic closing deactivated)
Pedestrian stroke duration adjustment
Pre-fl ashing time adjustment
Adjustment of phase displacement time while opening
Adjustment of phase displacement time while closing
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of
automatic opening and closing
Ram blow function: if=0 "Ram blow" function deactivated; if=1 it pushes the motors closed for one second
before each opening movement, so as to ease the releasing of any electric lock; if>1 it execute a periodic
pushing stroke so as to maintain the wings under pressure on the closing strokes. If closing limit switches
are installed, it performs this function only if they are not activated, i.g. when there's a pressure decrease
on the stroke.
"Reversal" mode selection (during the manoeuvre a command impulse reverse the mouvement) or "step by
step" (during the manoeuvre a command impulse stops the mouvement). A next impulse restart the operator
to the opposite direction.
Operation mode selection of the warning light output:
If = 0 "fi x warning light" (output always ON when the gate is open, OFF after a closing operation),
If> 1 "courtesy light" (output ON during each movement, OFF when the motor stops, after the setting delay).
Searches for end of stroke while opening too: when activated, operators stop only at their arrival et the end
of stroke, also while opening.
Warning: During the emergency operation (rESP), the motor executes the fi rst maneuver while opening. In
addition, if any limit switches, the parameter is forced to 1.
"soft start" function: motors accelerate gradually until they reach the set speed, avoiding sudden departures.
ONLY TYPE 02: If=3 the opening slow space (P035) also becomes the space within which the port moves at
slow speed (P031) and close start.
Warning: For operators without encoder, the parameter will be ingnored.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the opening.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the closing.
Facilitation manual release: If≠0, after ending the closing or opening maneuver, the engine reverses for
a brief time to release the pressure on it, and thus facilitate the manual release. The set value shows the
length of the inversion. If=0 function disabled
EN-26
PHOTO input functioning: If=0: photocell enabled while closing and starting when the gate is
stopped; if=1 photocells are always enabled; if=2 photocells are enabled while closing only.
PHOTO 1
When enabled, its activation provokes: the inversion (while closing), the stop (while opening)
and prevent the starting (when gate is closed).
If = 3-4-5, the operation is identical to values 0-1-2 but with the" close immediately "function
PHOTO 2
enabled: in any case, when opening and / or pausing time, removing a any obstacle the gate
will end the opening maneuver before closing it automatically after a 2 second fi xed delay.