Herunterladen Inhalt Inhalt Diese Seite drucken

Messages Shown On The Display; Error Messages - Dea NET230N Bedienungsanleitung Und Hinweise

Programmierbare steuereinheit
Vorschau ausblenden Andere Handbücher für NET230N:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 99

8 MESSAGES SHOWN ON THE DISPLAY

Mess.
Gate is closed
Gate is opened
Opening under way
Closing under way
While in step-by-step mode, the control board awaits further instructions after a start command
Stop input intervened or an obstacle is detected with limited inversion duration (P055 > 0 or P056 > 0)
Board in BOOT-MODE: Indicates that the fi rmware is corrupted or updating. To restore the fi rmware, use the DEAinstaller APP and make sure
NET-NODE is corrected to the correct port.
Warning: When updating the fi rmware, all data in the board memory (settings and radio commands) are lost. Make sure you have backed
up the memory to be restore data after the update.
Reset current position: The control unit has just been turned on after a power failure, or the gate has exceeded the maximum number (80) of in-
versions allowed without ever getting to the closing stroke, or the maximum number (15) of consecutive operations allowed of the anti- crushing
device.
Once the control unit has been reset and open command given the gate will start moving at slow speed, until it reaches end of travel.
Mess.
Error position: The reset position procedure is not suc-
cessful. The control panel is awaiting commands.
Board programming attempted when a NET-NODE
device is connected.
External photocells and/or safety devices are activated
or out of order.
Possible fault/overheating in the control unit's power
circuit.
Time-out operators run: The engine/s exceeded the
maximum operating time (4min) without ever stopping.
Time-out obstacle detection: With anti-crushing sensor
disabled, was still detected the presence of an obstacle
that prevents movement of the leaf for a period of 10
seconds more.
Operators mouvement not detected.
No/interrupted communication with remote memory
board (also NET-EXP or NET-NODE).
Possible fault/overheating in the control unit's power
circuit.
Possible malfunction in the control unit's power circuit
or in the encoder circuit.
Sensitive regulation parameters were edited via
DEAinstaller APP without running motor stroke learning
at the end of the operation.
NET-NODE connected to the incorrect communication
port.
EN-20
WORKING STATUS MESSAGES
Description
Description

ERROR MESSAGES

- Make sure there are no specifi c frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully, manually helping the run, if ne-
cessary;
- Adjust power and speed settings if necessary.
Turn off power, disconnect the NET-NODE from the communication port and turn back
on;
- Make sure that all safety devices and/or photocells installed are working properly.
Turn off power for several minutes and turn back on. Give a start command: if the
message is repeated, replace the control unit.
- Give a start pulse to start the position reset procedure;
- Ensure that this operation is successful.
- Make sure there are no specifi c frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully.
- Make sure that operators and encoders connections are well done.
- Check the setting of parameter P029 (Motor selection with or without encoder) and
make sure it is correct.
- If this error appears again, replace the control panel.
- Check that the connecting cable of the external memory card is connected properly.
- If you are performing a data transfer operation (DOWNLOAD / UPLOAD), make sure
that it is not interrupted (eg by unplugging the card before the end of the operation).
Please note: the interruption of an UPLOAD, also involves a total RESET of the control
unit.
Turn off power for several minutes and turn back on. Give a start command: if the
message is repeated, replace the control unit.
Check the wiring of the encoder and the motor. Shut the power supply off and on again.
Give a start command: if the message is repeated, perform the following checks.
- Enter P003 and move the door using the + and - buttons.
- If the door moves at maximum speed and the display shows Err7, replace the motor's
encoder card.
- If the motor still remains stationary, replace the control unit.
Run motor stroke learning (P003) fi rst to be able to run any other operation.
Connect NET-NODE to the correct port according to that indicated in the control unit
diagram.
Possible solutions

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis