Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT VC130 Bedienungsanleitung Seite 44

Digital-multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Direct voltage, overload protection 250 V
Range
Accuracy
VC130/150
200 mV
2,000 mV
±(0.5% + 8)
20 V
200 V
250 V
±(0,8% + 8)
Alternating voltage (40 – 400 Hz), overload protection 250 V
Range
Accuracy
(5 – 100% of the
VC130/150
measuring range)
200 V
±(1,5% + 8)
250 V
Direct current, overload protection 1A/250V + 10 A/250 V
Range
Accuracy
VC130
200 µA*
2000 µA
±(1,3% + 2)
20 mA
200 mA
±(1,5% + 8)
10 A
±(2,5% + 10) 0.01 A
* only with the VC130
Alternating current (only with VC170), overload protection 1A/250V + 10 A/250 V
Range (40 - 400 Hz)
400 µA
4,000 µA
40 mA
400 mA
4 A
10 A
44
Resolution
Range
VC170
0.1 mV
400 mV*
1 mV
4,000 mV
0.01 V
40 V
0.1 V
250 V
1 V
* With the VC170, the 400 mV measuring range
is only available via the manual measuring range
selection.
Resolution
Range
VC170
0.1 V
400 mV*
1 V
4,000 mV
40 V
250 V
* With the VC170, the 400 mV measuring range
is only available via the manual measuring range
selection.
Resolution
Range
VC170
0.1 µA
400 µA
1 µA
4,000 µA
0.01 mA
40 mA
0.1 mA
400 mA
4 A
10 A
Accuracy
±(1.6% + 5)
±(2.0% + 8)
±(2.6% + 4)
Accuracy
Resolution
±(0,8% + 8)
0.1 mV
1 mV
±(0,8% + 8)
0.01 V
0.1 V
Accuracy
Resolution
(5 – 100% of the
measuring range)
±(2,0% + 10)
0.1 mV
1 mV
±(1,6% + 4)
0.01 V
0.1 V
Accuracy
Resolution
±(1,3% + 2)
0.1 µA
1 µA
±(1,6% + 2)
0.01 mA
0.1 mA
±(2,0% + 10)
0.01 A
0.1 A
Resolution
0,1 µA
1 µA
0.01 mA
0.1 mA
0.001 A
0.01 A